EAM90 series water quality analyzer
Product Details

 The EAM90 series multi parameter single channel water quality analyzer adopts isolation current technology and can be connected to pH ORPMultiple types of digital sensors, including conductivity, flow rate, residual chlorine, temperature, etc., are suitable for most water treatment applications.

Performance characteristics:

Performance index

Performance parameter

Display

Large screen display with 128x128 pixels

Output signal

The EAM90 series is equipped with two normally open relays for chemical set point setting, probe cleaning, temperature measurement, and remote alarm; Two 4-20mA analog outputs and one pulse output, which can be set by the user themselves

Probe cleaning

When activating the probe cleaning cycle, relay 2 can be set. The cleaning method is based on three different stages: probe cleaning activation, delay time for measuring stability, and waiting for a new cleaning program

Relay activation

The relay activation method is based on three different steps: a) threshold activation; b) Timed activation; c) Proportional threshold timed activation

TDS function

The conductivity measurement value can be expressed in ppm units, which is particularly suitable for calculating the total dissolved solids in cooling tower water treatment and reverse osmosis industries


TDS function

The conductivity measurement value can be expressed in ppm units, which is particularly suitable for calculating the total dissolved solids in cooling tower water treatment and reverse osmosis industries

Temperature measurement

Relay 2, pulse output, and 4-20mA output can also be set for temperature measurement

Wizard calibration

Conventional wizard calibration can assist end users in probe maintenance and parameter settings

Alarm

The instrument can display a list of alarm information. The main alarm will be activated in the following situations: when the temperature exceeds the set range; Probe malfunction; Excessive dosing of OFA (errors caused by failure to reach the set point value within a given time and insufficient flow rate)

Power Supply

24Vdc,  115Vac,  230Vac three power settings, CE level 2 does not require grounding

Shell size

The casing comes in two sizes: 96x96mm, disc mounted, with a front panel protection level of IP65 and a rear panel protection level of IP20, 144x144mm, wall mounted, with a protection level of IP65 for the entire machine

Installation method

There are two installation methods: wall mounted and disc mounted

Measurement parameter indicators:

Measurement parameters

Measuring range

Measurement accuracy

pH

0~14 pH

± 0.01 pH

ORP

± 2,000 mV

± 5mV

Conductivity

0.054~400,000μS

± 5%

Traffic volume

0~99,999l/s

± 0.5 Hz

Membrane residual chlorine

0~200 ppm

± 0.01 ppm

Temperature

0~100°C

± 1°C

Dissolved oxygen

0~20 ppm

± 2%

Peracetic acid

0~99,000 ppm

± 0.01 ppm

Hydrogen peroxide solution

0~99,000 ppm

± 0.01 ppm

Bromine

0~10 ppm

± 0.01 ppm

Ozone

0~99,000 ppm

± 0.01 ppm

Turbidity

0~4.000 NTU

± 2 %

Sludge concentration

1~30g/L

± 1 %