Home > ETS-P
Product Details

ETS-P Magnetostrictive displacement sensor Product advantages:

² Strong and durable: Fully enclosed design, the highest IP68 protection level

² Straight line measurement Absolute output, no need to return to zero

² Easy to use: Standard signal output, maintenance free

² Never wear: Continuous non-contact measurement

² Full range adjustable: 100% adjustable zero and full range

² High resolution: The highest resolution is 0.5um

 

Technical parameter:

 

Input

Measurement data: location

Measurement range: 50mm-7650mm

 

Output

Voltage:0~10Vdc,10~0Vdc,0~5Vdc,5~0Vdc

(controller minimum load: >5k Ohms)

Electric current: 4~20mA,20~4mA,0~20mA,20~0mA

(minimum load: 0 Ohms / heavy load: 500 Ohms)

 

Accuracy

Resolution 16 bit D / A, up to 0.5um

Nonlinearity < 0.02% of full scale (minimum 100um)

Repeatability < 0.002% of full scale or the same as resolution

Update time 0.5ms (range ≤ 1200mm)

1.0ms (range ≤ 2400mm)

2.0ms (range ≤ 4800mm)

3.0ms (range ≤ 7650mm)

 

Working conditions

Magnetic ring speed: arbitrary

Working temperature :- 40 ~ 85 ℃

Humidity / dew point humidity :90%, no condensation

Temperature coefficient<30ppm / ℃

Protection grade:IP65 TP aluminum forming outer pipe

IP68 TH pressure resistant outer pipe (waterproof type)

 

Structure and materials

Electronic warehouse: Aluminum alloy profiles

Measuring rod: Aluminum alloy

Magnet: Slider magnet or floating magnet

Magnetic ring:Standard magnetic ring or open magnetic ring

Outer pipe pressure:  40MPa (continuous)

60MPa (peak value)

 

Install

Installation direction:arbitrary direction

Thread form: metric m18 × 1.5 ,M20 × 1.5

British system 3 / 4 “- 16UNF-3A

 

Electrical connection

Outlet type: waterproof connector or aviation plug

Input voltage: 24 VDC (- 15 ~ + 20%)

polarity protection Maximum :- 30VDC

Overpressure protection: Maximum36VDC

Working current <70mA (varies with measuring range)