ETS-P
ETS-P Magnetostrictive displacement sensor Product advantages:
² Strong and durable: Fully enclosed design, the highest IP68 protection level
² Straight line measurement Absolute output, no need to return to zero
² Easy to use: Standard signal output, maintenance free
² Never wear: Continuous non-contact measurement
² Full range adjustable: 100% adjustable zero and full range
² High resolution: The highest resolution is 0.5um
Technical parameter:
Input
Measurement data: location
Measurement range: 50mm-7650mm
Output
Voltage:0~10Vdc,10~0Vdc,0~5Vdc,5~0Vdc
(controller minimum load: >5k Ohms)
Electric current: 4~20mA,20~4mA,0~20mA,20~0mA
(minimum load: 0 Ohms / heavy load: 500 Ohms)
Accuracy
Resolution 16 bit D / A, up to 0.5um
Nonlinearity < 0.02% of full scale (minimum 100um)
Repeatability < 0.002% of full scale or the same as resolution
Update time 0.5ms (range ≤ 1200mm)
1.0ms (range ≤ 2400mm)
2.0ms (range ≤ 4800mm)
3.0ms (range ≤ 7650mm)
Working conditions
Magnetic ring speed: arbitrary
Working temperature :- 40 ~ 85 ℃
Humidity / dew point humidity :90%, no condensation
Temperature coefficient<30ppm / ℃
Protection grade:IP65 TP aluminum forming outer pipe
IP68 TH pressure resistant outer pipe (waterproof type)
Structure and materials
Electronic warehouse: Aluminum alloy profiles
Measuring rod: Aluminum alloy
Magnet: Slider magnet or floating magnet
Magnetic ring:Standard magnetic ring or open magnetic ring
Outer pipe pressure: 40MPa (continuous)
60MPa (peak value)
Install
Installation direction:arbitrary direction
Thread form: metric m18 × 1.5 ,M20 × 1.5
British system 3 / 4 “- 16UNF-3A
Electrical connection
Outlet type: waterproof connector or aviation plug
Input voltage: 24 VDC (- 15 ~ + 20%)
polarity protection Maximum :- 30VDC
Overpressure protection: Maximum36VDC
Working current <70mA (varies with measuring range)