ETS-H
ETS-H Magnetostrictive displacement sensor during the measurement, the electronic components of the Electronic Chamber of the sensor generate a current pulse, which generates a magnetic field to move along the waveguide wire. The movable magnetic ring on the sensor rod also generates a magnetic field. When the magnetic field generated by the current intersects the magnetic field generated by the magnetic ring, the waveguide wire produces a magnetostrictive effect, producing a strain pulse. The pulse travels back along the waveguide wire at a fixed speed and is detected by the measuring element. By measuring the time between the current pulse and the strain pulse, the position (displacement) of the magnetic ring can be accurately determined.
Technical parameters:
Input
Measurement range: 50mm-7650mm
Output
Voltage:0~10V dc,10~0V dc,0~5V dc,5~0V dc
(controller minimum load: >5k Ohms)
Electric current: 4~20mA,20~4mA,0~20mA,20~0mA
(minimum load: 0 Ohms / heavy load: 500 Ohms)
Accuracy
Resolution 16 bit D / A, up to 0.5um
Nonlinearity < 0.02% of full scale (minimum 100um)
Repeatability < 0.002% of full scale or the same as resolution
Update time 0.5ms (range ≤ 1200mm)
1.0ms (range ≤ 2400mm)
2.0ms (range ≤ 4800mm)
5.0ms (range ≤ 7650mm)
Working conditions
Magnetic ring speed: arbitrary
Working temperature :- 40 ~ 85 ℃
Humidity/dew point humidity :90%, no condensation
Temperature coefficient<30ppm / ℃
Protection grade:IP65 RP aluminum forming outer pipe
IP68 RH pressure resistant outer pipe (waterproof type)
Structure and materials
Electronic warehouse: Aluminum alloy profiles
Magnet: Slider magnet or floating magnet
Measuring rod:stainless steel 304 or 316L
Magnetic ring:Standard magnetic ring or open magnetic ring
Outer pipe pressure 40MPa (continuous)
60MPa (peak value)
Install
Installation direction:arbitrary direction
Thread form: metric m18 × 1.5 ,M20 × 1.5
British system 3 / 4 “- 16UNF-3A
Electrical connection
Outlet type: waterproof connector or aviation plug
Input voltage: 24 VDC (- 15 ~ + 20%)
polarity protection Maximum :- 30VDC
Overpressure protection: Maximum 36VDC
Working current: <70mA (varies with measuring range)
Scope of application:suitable to Built-in compact structure, suitable for the built-in installation of hydraulic cylinders.