Home > ETS-H
Product Details

ETS-H Magnetostrictive displacement sensor during the measurement, the electronic components of the Electronic Chamber of the sensor generate a current pulse, which generates a magnetic field to move along the waveguide wire. The movable magnetic ring on the sensor rod also generates a magnetic field. When the magnetic field generated by the current intersects the magnetic field generated by the magnetic ring, the waveguide wire produces a magnetostrictive effect, producing a strain pulse. The pulse travels back along the waveguide wire at a fixed speed and is detected by the measuring element. By measuring the time between the current pulse and the strain pulse, the position (displacement) of the magnetic ring can be accurately determined.

Technical parameters:

Input

Measurement range: 50mm-7650mm

 

Output

Voltage:0~10V dc,10~0V dc,0~5V dc,5~0V dc

(controller minimum load: >5k Ohms)

Electric current: 4~20mA,20~4mA,0~20mA,20~0mA

(minimum load: 0 Ohms / heavy load: 500 Ohms)

 

Accuracy

Resolution 16 bit D / A, up to 0.5um

Nonlinearity < 0.02% of full scale (minimum 100um)

Repeatability < 0.002% of full scale or the same as resolution

Update time 0.5ms (range ≤ 1200mm)

1.0ms (range ≤ 2400mm)

2.0ms (range ≤ 4800mm)

5.0ms (range ≤ 7650mm)

 

Working conditions

Magnetic ring speed: arbitrary

Working temperature :- 40 ~ 85 ℃

Humidity/dew point humidity :90%, no condensation

Temperature coefficient<30ppm / ℃

Protection grade:IP65 RP aluminum forming outer pipe

IP68 RH pressure resistant outer pipe (waterproof type)

 

Structure and materials

Electronic warehouse: Aluminum alloy profiles

Magnet: Slider magnet or floating magnet

Measuring rod:stainless steel 304 or 316L

Magnetic ring:Standard magnetic ring or open magnetic ring

Outer pipe pressure 40MPa (continuous)

60MPa (peak value)

 

Install

Installation direction:arbitrary direction

Thread form: metric m18 × 1.5 ,M20 × 1.5

British system 3 / 4 “- 16UNF-3A

 

Electrical connection

Outlet type: waterproof connector or aviation plug

Input voltage: 24 VDC (- 15 ~ + 20%)

polarity protection Maximum :- 30VDC

Overpressure protection: Maximum 36VDC

Working current:    <70mA (varies with measuring range)

 

Scope of application:suitable to Built-in compact structure, suitable for the built-in installation of hydraulic cylinders.